Re: What is the mechanical condition of the Low V?

Posted by Gerry6309 on Thu Aug 7 11:07:57 2008, in response to Re: What is the mechanical condition of the Low V?, posted by Jeff H. on Wed Aug 6 21:56:51 2008.

edf40wrjww2msgDetail:detailStr
fiogf49gjkf0d
Interesting combination of failures. Thanks for the rundown. I understand perfectly the combination of events and why a fuse didn't blow. Murphy does state thatif you design for 10 ways something can go wrong, an 11th will develop. Oddly, the same failure might not happen on our Orange Line 0900s at Seashore, since the leakage current might not be enough to close the Hi-V Line Breaker. Then again...